DingzhouAmerican-style substation

The ZGS11-□-12/0.4 series prefabricated American-style pad-mounted substation, commonly referred to as an “American substation,” “American-type pad-mounted substation,” or “combined transformer,” is an outdoor pad-mounted substation in which the transformer core, high-voltage load switch, fuses, and other components are all housed within a single transformer oil tank, while the low-voltage compartment is enclosed in a single, integral outdoor cabinet that is further divided into metering, incoming line, outgoing line, and capacitor compartments, all compactly assembled together.

Product Description

   Product Definition

  The ZGS11-□-12/0.4 series prefabricated American-style pad-mounted substation, often referred to as an “American transformer,” “American-style pad-mounted substation,” or “combined transformer,” is an outdoor pad-mounted substation in which the transformer core, high-voltage load switch, fuses, and other components are all housed within a single transformer oil tank, while the low-voltage compartment is enclosed in a single, integral outdoor cabinet that is further divided into metering, incoming line, outgoing line, and capacitor compartments, all compactly assembled together.

 

   Main Technical Parameters of the Product

Serial Number

Project

Unit

Parameters

1

Rated voltage

kilovolt

10/0.4 (high voltage/low voltage)

2

Maximum operating voltage

kilovolt

12 (High-Voltage Side)

3

Rated frequency

Hertz

50

4

Rated capacity

kVA

150-1600

5

1-minute power-frequency withstand voltage

kilovolt

35

6

Lightning Impulse Voltage

kilovolt

75

7

Cooling method

\

Oil-immersed, self-cooled

8

Breaking current of high-voltage back-side fuse

kA

50

9

Breaking current of plug-in fuses

kA

2.5

10

Ambient temperature

degrees Celsius

-35~+40

11

Sequential Warming of Coils

k

65

12

No-load voltage regulation

\

±5% or ±2 × 2.5%

13

Noise Level

database

50

14

Protection Level

\

IP43

 

   Selling Points and Advantages

  1. Compact structure and small footprint—only about 1/3 to 1.5 times that of a domestically produced European-style pad-mounted substation of the same capacity—significantly reducing the required land area.

  2. Fully sealed and fully insulated design eliminates the need for clearance distances, providing reliable protection for personal safety.

  3. High-voltage wiring can be used for both ring networks and terminal applications, offering flexible power supply configurations and high reliability.

  4. Outstanding transformer performance: low losses, low noise, and low temperature rise; strong overload capability, excellent short-circuit resistance, and high impact withstand capability.

  5. Meets various low-voltage feeder requirements; options can be selected based on the scheme, or a custom design can be developed.

  6. The cable terminations are available in two types: a 200 A elbow-type plug and a 600 A “T”-type fixed cable connector. Both can be equipped with fully insulated zinc oxide surge arresters. The 200 A cable termination allows for load-break connection and disconnection and can also function as an isolating switch.