ZN85-40.5 Type Vacuum Circuit Breaker
The ZN85-40.5 indoor high-voltage AC vacuum circuit breaker is designed for use in indoor handcart-type switchgear with a three-phase AC supply of 50 Hz and a rated voltage of 40.5 kV. It is intended for switching load currents, overload currents, and fault currents in industrial and mining enterprises, power plants, and substations, and is suitable for applications requiring frequent operation. The circuit breaker is designed, manufactured, and tested in accordance with GB/T 1984 and relevant standards.
Keywords: High- and low-voltage complete sets – packaged substations – ring main units
Category:
Contact Us
Product Description
Product Definition
The ZN85-40.5 indoor high-voltage AC vacuum circuit breaker is designed for use in three-phase, 50 Hz, 40.5 kV indoor handcart-type switchgear, serving industrial and mining enterprises, power plants, and substations as a device for switching load currents, overload currents, and fault currents, and is also suitable for applications requiring frequent operations. The circuit breaker is designed, manufactured, and tested in accordance with GB/T 1984 and relevant standards.
Normal operating conditions
1. Ambient temperature shall not exceed +40°C or fall below -10°C (storage and transportation are permitted at -30°C).
2. Altitude shall not exceed 1,500 m.
3. Relative humidity: the daily average shall not exceed 95%, the monthly average shall not exceed 90%, and the daily average of saturated vapor pressure shall not exceed 2.2 × 10⁻³ MPa, with the monthly average not exceeding 1.8 × 10⁻³ MPa.
4. The seismic intensity shall not exceed 8 degrees.
5. Locations free from fire hazards, explosion risks, severe contamination, chemical corrosion, and violent vibrations.
Main Technical Parameters of the Product
| Name | Unit | Data |
| Rated voltage | kilovolt | 40.5 |
| 1-minute power-frequency withstand voltage (RMS) | kilovolt | 95 |
| Lightning Impulse Withstand Voltage (Peak) | kilovolt | 185 |
| Rated frequency | Hertz | 50 |
| Rated current | A | 1250/1600/2000/2500 |
| Rated short-time withstand current | kA | 20/25/31.5 |
| Rated Peak Withstand Current | kA | 50/63/80 |
| Rated short-circuit duration | s | 4 |
| Rated short-circuit breaking current | kA | 20/25/31.5 |
| Rated short-circuit making current | kA | 50/63/80 |
| Rated Operating Sequence | O-0.3s-CO-180s-CO | |
| Breaking time | millisecond | <80 |
| Rated short-circuit breaking current breaking operations | next | 20 |
| Breaking current of a single capacitor bank | A | 630 |
| Breaking current of back-to-back capacitor banks | A | 400 |
| Rated operating voltage | v | AC/DC 110, 220 |
| Mechanical life | next | 10000 |